Decoded GOES message
PR310 24-Jan-2024 17:32:46 GOES DCP id=04409036
TX time:24-Jan-2024 17:32:46
failure code:?
signal strength:29
data quality:P
message length:288
message:
0440903624024173246?29+0NP181EXE00288`@_hDe`@ZuDU~Dk_EVK@YlGNHD\HDW\FJTEedDjLFMX@eaD\HDW\FJJMedDjLFMcDggF@@F@@F@@F@@F@@F@@I|~BNBEuAI|~I|~I|~@yD@xz@yPFnRG`dDSYDOpBLhDLDTfFOhI|~@_hBSX@ZgI|~I|~I|~F@@NAfF_nDOhFojEYDE@DKmlGNHFIEDjSI|+"$n$8$$$$$J$$g$$y"$$$E$:$$$$$$$$$?$$$$ $$75$?$$$6$$$$13 $$ $$$$$$$$1$$7$$$0<9$$$

#field namevalueinstrument
group
0clock_year 2024common
1clock_doy 24common
2clock_hhmm 1717common
3battery 14.06diagnostics
4int_temp 27.83diagnostics
5water_level 55.15diagnostics
6gps_time 1644diagnostics
7gps_seconds 5diagnostics
8gps_lat_degrees 18diagnostics
9gps_lat_minutes 15diagnostics
10gps_lat_minutes_fraction 0.66diagnostics
11gps_lon_degrees 65diagnostics
12gps_lon_minutes 27diagnostics
13gps_lon_minutes_fraction 0.856diagnostics
14gps_date 2401diagnostics
15gps_alt_lat_degrees 18diagnostics
16gps_alt_lat_minutes 15diagnostics
17gps_alt_lat_minutes 0.65diagnostics
18gps_alt_lon_degrees -65diagnostics
19gps_alt_lon_minutes 27diagnostics
20gps_alt_lon_minutes_fraction 0.867diagnostics
21air_temperature 25.35met
22wind_min 0met
23wind_gust 0met
24wind_speed_sc 0met
25wind_direction_uv 0met
26wind_direction_uv_stddev 0met
27wind_gust_1s 0met
28wind_percent_good -7998met
29compass 89.8met
30compass_stddev 74.89met
31visibility_counts -7998met
32min_visibility_counts -7998met
33max_visibility_counts -7998met
34barometric_pressure_counts 3652met
35barometric_pressure_min_counts 3642met
36barometric_pressure_max_counts 3664met
37barometric_pressure_stddev_counts 2.962met
38wind_2_min 6.18met
39wind_2_gust 12.41met
40wind_2_speed_sc 10.08met
41wind_2_direction_uv 80.8met
42wind_2_direction_uv_stddev 8.31met
43wind_2_gust_1s 13.18met
44wind_2_percent_good 1met
45spare -7998common
46year 2024met
47mmdd 124met
48hhmm 1703met
49spare -7998common
50spare -7998common
51spare -7998common
52spare 0common
53significant_wave_height-0.102waves
54dominant_wave_period 2.03waves
55max_wave_height 10waves
56mean_wave_direction 3.05waves
57mean_wave_direction_spread 57waves
58spare 41common
59checksum -702common
60conductivity_integer 5ct
61conductivity_fraction 0.581ct
62temperature 27.07ct
63spare -7979common
64SkippedScan 235diagnostics
65SkippedSystemScan 36diagnostics
66MaxBuffDepth 23.4diagnostics
67SkippedSlowScan 23.14diagnostics
68SkippedSlowScan 23.43diagnostics
69SkippedSlowScan 64.36diagnostics
70spare-77.78common
71MaxBat 23.4diagnostics
72MinBat 64.58diagnostics
73SIO4_trigger_count 23.28diagnostics
74SIO41_1_count 2.31diagnostics
75SIO41_2_count 23.4diagnostics
76SIO41_3_count 23.4diagnostics
77SIO41_4_count-816.4diagnostics
78SIO42_1_count 23.4diagnostics
79SIO42_2_count-496.4diagnostics
80SIO42_3_count 35.73diagnostics
81SIO42_4_count 40.68diagnostics
82spare -23.4common
83spare 2.34common
84volts 18.28accelerometer
85volts 7392accelerometer
86volts 23.36accelerometer
87volts 23.4accelerometer
88volts 643.6accelerometer
89volts 13.16accelerometer
90volts 31.72accelerometer
91volts 15.91accelerometer
92volts 23.4accelerometer
93volts 3897accelerometer
94volts 23.31accelerometer
95voltsaccelerometer