Decoded GOES message
PR116 03-Dec-2024 00:32:30 GOES DCP id=04408340
TX time:03-Dec-2024 00:32:30
failure code:?
signal strength:43
data quality:P
message length:263
message:
0440834024338003230?43+1NP181EUP00263`@_hBttF@@DS{DoJEYU@dhDe`DZdEQPFCGEgHDr@FCgBaHDZdEQPFBwMgHDr@FCiDlwGI`DRPGk[BMYGxLDjdI|~BmAER}I|~I|~I|~@ws@wo@wzF[iGCjDMqGkoBN@GxXDOPFOhI|~@_h@RsF~`I|~I|~I|~FAfFQBGhlF\\BVjDhhAHRCfwGNHFJ{Dm]I|~DNDF@@Fn($y$$$]$T$$H?$A$$$$$$$$$$$$$$$Q$u$C$$$$$O$p$|o $$V$+$$$$d

#field namevalueinstrument
group
0clock_year 2024common
1clock_doy 338common
2clock_hhmm 0common
3battery 12.75diagnostics
4int_temp 30.18diagnostics
5water_level 57.17diagnostics
6gps_time 2344diagnostics
7gps_seconds 24diagnostics
8gps_lat_degrees 17diagnostics
9gps_lat_minutes 52diagnostics
10gps_lat_minutes_fraction 0.199diagnostics
11gps_lon_degrees 66diagnostics
12gps_lon_minutes 32diagnostics
13gps_lon_minutes_fraction 0.231diagnostics
14gps_date 212diagnostics
15gps_alt_lat_degrees 17diagnostics
16gps_alt_lat_minutes 52diagnostics
17gps_alt_lat_minutes 0.183diagnostics
18gps_alt_lon_degrees -66diagnostics
19gps_alt_lon_minutes 32diagnostics
20gps_alt_lon_minutes_fraction 0.233diagnostics
21air_temperature 28.71met
22wind_min 4.704met
23wind_gust 11.68met
24wind_speed_sc 6.875met
25wind_direction_uv 85.7met
26wind_direction_uv_stddev 7.692met
27wind_gust_1s 27.24met
28wind_percent_good -7998met
29compass 288.1met
30compass_stddev 53.09met
31visibility_counts -7998met
32min_visibility_counts -7998met
33max_visibility_counts -7998met
34barometric_pressure_counts 3571met
35barometric_pressure_min_counts 3567met
36barometric_pressure_max_counts 3578met
37barometric_pressure_stddev_counts 1.769met
38wind_2_min 4.33met
39wind_2_gust 8.81met
40wind_2_speed_sc 6.895met
41wind_2_direction_uv 89.6met
42wind_2_direction_uv_stddev 7.704met
43wind_2_gust_1s 9.76met
44wind_2_percent_good 1met
45spare -7998common
46year 2024met
47mmdd 1203met
48hhmm 4met
49spare -7998common
50spare -7998common
51spare -7998common
52spare 0.102common
53significant_wave_height 1.09waves
54dominant_wave_period 6.7waves
55max_wave_height 1.82waves
56mean_wave_direction 145waves
57mean_wave_direction_spread 26waves
58spare 4626common
59checksum 658.3common
60conductivity_integer 5ct
61conductivity_fraction 0.699ct
62temperature 29.09ct
63spare -7998common
64SkippedScan 9diagnostics
65SkippedSystemScan 0diagnostics
66MaxBuffDepth 2.984diagnostics
67SkippedSlowScan 36.84diagnostics
68SkippedSlowScan 23.33diagnostics
69SkippedSlowScan 13.16diagnostics
70spare 5.75common
71MaxBat 1diagnostics
72MinBat 23.4diagnostics
73SIO4_trigger_count 23.35diagnostics
74SIO41_1_count 23.4diagnostics
75SIO41_2_count 23.4diagnostics
76SIO41_3_count 23.4diagnostics
77SIO41_4_count 6453diagnostics
78SIO42_1_count 2.28diagnostics
79SIO42_2_count 23.4diagnostics
80SIO42_3_count-640.8diagnostics
81SIO42_4_count-6.448diagnostics
82spare 38.87common
83spare-64.36common
84volts 2.347accelerometer
85volts 23.4accelerometer
86volts 18.28accelerometer
87voltsaccelerometer