Decoded GOES message
PR114 28-Jun-2022 08:32:30 GOES DCP id=04408340
TX time:28-Jun-2022 08:32:30
failure code:?
signal strength:44
data quality:P
message length:253
message:
0440834022179083230?44+1NP181EN200253`@_fB[~@LhDSdDnaEYBCtZDuHDZdEQPFAvEgHDp\FNc@kvDZdEQPFAuMgHDp\FNfDkZFtDGvuGTYEkXDQXDLdI|~BkcEVoI|~I|~I|~@xK@xG@xPFULFpzGqtGRvEkDDNBGzVFOhI|~@_fCbH$$X4{$Q$DN$F$\$$|$ $+$ S$-$$$$v$X-$E$$$3o) $$ $$/3$$$3$$?$$$$$$$$$$$$$0$$K$$$$$$$$$U$$$$>$Wd _$$$f$E7$

#field namevalueinstrument
group
1clock_year 2022common
2clock_doy 179common
3clock_hhmm 808common
4battery 12.52diagnostics
5int_temp 29.77diagnostics
6water_level 56.98diagnostics
7gps_time 745diagnostics
8gps_seconds 34diagnostics
9gps_lat_degrees 17diagnostics
10gps_lat_minutes 52diagnostics
11gps_lat_minutes_fraction 0.118diagnostics
12gps_lon_degrees 66diagnostics
13gps_lon_minutes 31diagnostics
14gps_lon_minutes_fraction 0.931diagnostics
15gps_date 2806diagnostics
16gps_alt_lat_degrees 17diagnostics
17gps_alt_lat_minutes 52diagnostics
18gps_alt_lat_minutes 0.117diagnostics
19gps_alt_lon_degrees -66diagnostics
20gps_alt_lon_minutes 31diagnostics
21gps_alt_lon_minutes_fraction 0.934diagnostics
22air_temperature 27.78met
23wind_min 3.332met
24wind_gust 7.605met
25wind_speed_sc 5.401met
26wind_direction_uv 68.72met
27wind_direction_uv_stddev 11.12met
28wind_gust_1s 8.04met
29wind_percent_good -7998met
30compass 278.7met
31compass_stddev 55.51met
32visibility_counts -7998met
33min_visibility_counts -7998met
34max_visibility_counts -7998met
35barometric_pressure_counts 3595met
36barometric_pressure_min_counts 3591met
37barometric_pressure_max_counts 3600met
38barometric_pressure_stddev_counts 1.356met
39wind_2_min 3.13met
40wind_2_gust 7.284met
41wind_2_speed_sc 5.302met
42wind_2_direction_uv 68.52met
43wind_2_direction_uv_stddev 8.98met
44wind_2_gust_1s 7.83met
45wind_2_percent_good 1met
46spare -7998common
47year 2022met
48mmdd 628met
49hhmm 23.19met
50spare -3387common
51spare 11.24common
52spare 9.32common
53spare 2.332common
54significant_wave_height 23.64waves
55dominant_wave_period 8.04waves
56max_wave_height-643.2waves
57mean_wave_direction 644.5waves
58mean_wave_direction_spread 23.4waves
59spare 34.92common
60checksum -2916common
61conductivity_integer 64.36ct
62conductivity_fraction 33.11ct
63temperature -4708ct
64spare 7.4common
65SkippedScan 30.59diagnostics
66SkippedSystemScan 23.4diagnostics
67MaxBuffDepth 739.6diagnostics
68SkippedSlowScan 40.68diagnostics
69SkippedSlowScan 23.4diagnostics
70SkippedSlowScan -6436diagnostics
71spare 23.4common
72MaxBat 6436diagnostics
73MinBat 23.52diagnostics
74SIO4_trigger_count 23.15diagnostics
75SIO41_1_count 17diagnostics
76SIO41_2_count 23.4diagnostics
77SIO41_3_count 23.4diagnostics
78SIO41_4_count 13.8diagnostics
79SIO42_1_count 23.4diagnostics
80SIO42_2_count-2.327diagnostics
81SIO42_3_count 6.71diagnostics
82SIO42_4_count 23.4diagnostics
83spare 2.309common
84spare 6.432common