Decoded GOES message
N0118 06-Jun-2015 21:24:18 GOES DCP id=04416248
TX time:06-Jun-2015 21:24:18
failure code:?
signal strength:46
data quality:P
message length:24
message:
0441624815157212418?46-0HP181EXE00024b@__BXb@aIDVXDQbENe@$'$

#field namevalueinstrument
group
0clock_year 2015common
1clock_doy 157common
2clock_hhmm 2121common
3battery 14.32diagnostics
4int_temp 11.22diagnostics
5water_level 50.29diagnostics
6gps_time 2343diagnostics
7gps_secondsdiagnostics