Decoded GOES message
M0132 03-May-2023 05:24:35 GOES DCP id=0441713E
TX time:03-May-2023 05:24:35
failure code:?
signal strength:38
data quality:P
message length:596
message:
0441713E23123052435?38-0NP181EXE00596@@_gBSNCNzDS_DN@EQDCGFE@DECLDmTFFTEhlEQPFMOBojECLDmTFFPMhlEQPFMRGdCFCDFCDFCDBQXEVAFCDI|~BwZEaK@g@@g@@g@@so@sf@swFq[I|~I|~I|~I|~I|~I|~F@@F@@I|~I|~I|~I|~I|~I|~I|~I|~I|~I|~I|~F@@F@@Ha?F@@F@@F@@FnxFDHGmAI|~I|~I|~Dr@FL?GerI|~I|~I|~DytF@DDNzDytFHuDOQF@@F@@F@@FABFBNFTUF`|FwcGapG``GpaGboGUYG[uF|wFsKFx[G@XF^NFVkFNQFILFDIFCgFB^FAyFAtF@vFAEF@zF@jF@vF@]F@]F@@DQc@_gBSNCDzE@DFgqF?cFAnDNMBW{B\`FLVFJ|BaRFnxFKsDOPF@@F@@F@@DQcF@@F@@F@@F@@F@@BfiF@@GJQFxFFppFyLFm@GJVDNTDNVDOIDNkGJRD[VD\LD[hD]NGJRDbJDbkDclDdgGJRDnKDoaDlmDnEF@@F@@F@@F@@F@@Ca|@B`@@t@@W@@E@@C@@D@@x@$ EU=$f$T$$Z@$\s$$W$$$$$($$$g$$$nd@$>$+3$@$

#field namevalueinstrument
group
1clock_year 2023common
2clock_doy 123common
3clock_hhmm 505common
4battery 12.47diagnostics
5int_temp 8.96diagnostics
6water_level 51.88diagnostics
7gps_time 455diagnostics
8gps_seconds 41diagnostics
9gps_lat_degrees 43diagnostics
10gps_lat_minutes 29diagnostics
11gps_lat_minutes_fraction 0.404diagnostics
12gps_lon_degrees 67diagnostics
13gps_lon_minutes 52diagnostics
14gps_lon_minutes_fraction 0.847diagnostics
15gps_date 305diagnostics
16gps_alt_lat_degrees 43diagnostics
17gps_alt_lat_minutes 29diagnostics
18gps_alt_lat_minutes 0.4diagnostics
19gps_alt_lon_degrees -67diagnostics
20gps_alt_lon_minutes 52diagnostics
21gps_alt_lon_minutes_fraction 0.85diagnostics
22air_temperature 6.403met
23wind_min 0.196met
24wind_gust 0.196met
25wind_speed_sc 0.196met
26wind_direction_uv 111.2met
27wind_direction_uv_stddev 55.05met
28wind_gust_1s 0.196met
29wind_percent_good -7998met
30compass 354.6met
31compass_stddev 62.19met
32visibility_counts 2496met
33min_visibility_counts 2496met
34max_visibility_counts 2496met
35barometric_pressure_counts 3311met
36barometric_pressure_min_counts 3302met
37barometric_pressure_max_counts 3319met
38barometric_pressure_stddev_counts 3.163met
39wind_2_min -7998met
40wind_2_gust -7998met
41wind_2_speed_sc -7998met
42wind_2_direction_uv -7998met
43wind_2_direction_uv_stddev -7998met
44wind_2_gust_1s -7998met
45wind_2_percent_good 0met
46wind_gust_hourly 0met
47wind_gust_hourly_time -7998met
48wind_gust_hourly_seconds -7998met
49wind_2_gust_hourly -7998met
50wind_2_gust_hourly_time -7998met
51wind_2_gust_hourly_seconds -7998met
52wind_2_total_1s_samples -7998met
53wind_2_valid_1s_samples -7998met
54spare -7998common
55spare -7998common
56spare -7998common
57spare -7998common
58signal_strength_counts 0aanderaa
59tilt_counts 0aanderaa
60checksum -2175common
61conductivity_integer_001m 0ct
62conductivity_fraction_001m 0ct
63temperature_001m 0ct
64conductivity_integer_010m 3ct
65conductivity_fraction_010m 0.264ct
66temperature_010m 6.977ct
67conductivity_integer_020m -7998ct
68conductivity_fraction_020m -7998ct
69temperature020m -7998ct
70conductivity_integer_050m 32ct
71conductivity_fraction_050m 0.831ct
72temperature_050m 6.514ct
73conductivity_integer_100m -7998ct
74conductivity_fraction_100m -7998ct
75temperature_100m -7998ct
76conductivity_integer_150m 37ct
77conductivity_fraction_150m 0.004ct
78temperature_150m 9.54ct
79conductivity_integer_200m 37ct
80conductivity_fraction_200m 0.565ct
81temperature_200m 9.77ct
82current_speed_counts 0aanderaa
83current_direction_counts 0aanderaa
84temperature_counts 0aanderaa
85volts 0.066accelerometer
86volts 0.142accelerometer
87volts 1.301accelerometer
88volts 2.108accelerometer
89volts 3.555accelerometer
90volts 6.256accelerometer
91volts 6.176accelerometer
92volts 7.201accelerometer
93volts 6.319accelerometer
94volts 5.465accelerometer
95volts 5.877accelerometer
96volts 3.895accelerometer
97volts 3.275accelerometer
98volts 3.611accelerometer
99volts 4.12accelerometer
100volts 1.934accelerometer
101volts 1.451accelerometer
102volts 0.913accelerometer
103volts 0.588accelerometer
104volts 0.265accelerometer
105volts 0.231accelerometer
106volts 0.158accelerometer
107volts 0.121accelerometer
108volts 0.116accelerometer
109volts 0.054accelerometer
110volts 0.069accelerometer
111volts 0.058accelerometer
112volts 0.042accelerometer
113volts 0.054accelerometer
114volts 0.029accelerometer
115volts 0.029accelerometer
116spare 0common
117spare 11.23common
118year 2023waves3
119doy 123waves3
120hhmm 441waves3
121seconds 41waves3
122significant_wave_height_3 2.545waves3
123maximum_wave_height_3 4.067waves3
124dominant_wave_frequency_3 0.11waves3
125dominant_wave_period_3 9.09waves3
126mean_wave_direction_3 153.1waves3
127principal_wave_direction_3 182.4waves3
128R1_3 0.79waves3
129R2_3 0.7waves3
130checksum 213common
131conductivity_integer250m 3ct
132conductivity_fraction250m 0.755ct
133temperature250m 9.76ct
134conductivity_integer 0ct
135conductivity_fraction 0ct
136temperature 0ct
137pressure10m 11.23ct
138pressure 0ct
139pressure 0ct
140pressure 0ct
141pressure 0ct
142pressure 0ct
143pressure250m 247.3ct
144pressure 0ct
145time 4.753suna1
146nt 3.59suna1
147nt 3.12suna1
148nt 3.66suna1
149nt 2.88suna1
150time 4.758suna2
151nt 9.16suna2
152nt 9.18suna2
153nt 9.69suna2
154nt 9.39suna2
155time 4.754suna3
156nt 17.5suna3
157nt 18.04suna3
158nt 17.68suna3
159nt 18.7suna3
160time 4.754suna4
161nt 21.86suna4
162nt 22.19suna4
163nt 22.84suna4
164nt 23.43suna4
165time 4.754suna5
166nt 29.55suna5
167nt 30.41suna5
168nt 28.61suna5
169nt 29.49suna5
170spare 0common
171spare 0common
172spare 0common
173spare 0common
174spare 0common
175checksum 626.8common
176ens3160doppler
177ens252doppler
178year23doppler
179month5doppler
180day3doppler
181hour4doppler
182minute56doppler
183ens12316doppler
184amps21885doppler
185volts-112251doppler
186int_temp-113580doppler
187current_u_counts-112358doppler
188current_v_counts932doppler
189current_u_counts117988doppler
190current_v_counts-113180doppler
191current_u_counts92452doppler
192current_v_counts-112344doppler
193current_u_counts-112348doppler
194current_v_counts-100060doppler
195current_u_counts-111708doppler
196current_v_counts2366doppler
197current_u_counts-111885doppler
198current_v_counts-114652doppler
199current_u_countsdoppler