Decoded GOES message
E0142 26-Feb-2024 11:26:50 GOES DCP id=044200A0
TX time:26-Feb-2024 11:26:50
failure code:?
signal strength:30
data quality:N
message length:75
message:
044200A024057112650?30-0HN181EXE00075 @_hEYD@QWDSiGOTEQ@@P`DL`ECLEAhFNoEktD`tFCaDhhECLEAhFN$"$$d$$$$)$n$C$_

#field namevalueinstrument
group
0clock_year 2024common
1clock_doy 57common
2clock_hhmm 1111common
3battery 12.57diagnostics
4int_temp 5.076diagnostics
5water_level 51.84diagnostics
6gps_time 1056diagnostics
7gps_seconds 8diagnostics
8gps_lat_degrees 43diagnostics
9gps_lat_minutes 42diagnostics
10gps_lat_minutes_fraction 0.943diagnostics
11gps_lon_degrees 69diagnostics
12gps_lon_minutes 21diagnostics
13gps_lon_minutes_fraction 0.225diagnostics
14gps_date 26diagnostics
15gps_alt_lat_degrees 43diagnostics
16gps_alt_lat_minutes 42diagnostics
17gps_alt_lat_minutes 0.932diagnostics
18gps_alt_lon_degrees-63.08diagnostics
19gps_alt_lon_minutes 23.4diagnostics
20gps_alt_lon_minutes_fraction 2.28diagnostics
21air_temperature 26.6met
22wind_min-2.334met
23wind_gust 642.3met
24wind_speed_scmet