Decoded GOES message
A0144 11-Oct-2021 13:28:35 GOES DCP id=04427630
TX time:11-Oct-2021 13:28:35
failure code:G
signal strength:38
data quality:N
message length:781
message:
0442763021284132835G38+0NN181EN100782@@_eBlX@TaDT}D]WEPJ@SgDW\EAhDp\FF~EmXDsdFOB@QVEAhDp\FFqMmXDsdFOXDYxFgtGJGF|CEraDUDGOhI|~DYCEBQ@f~@f~@f~@\e@\c@\hFIIFeBGErF{?ElxDSdGWBFOhC]HI|~I|~I|~I|~I|~I|~I|~B`FErFDPzI|~MDiGTkHXwF@@F@@F@@F@@F~`FA_DZIGaxE@DFEEDZXF@@FnxFJcDQWENnI|~I|~I|~I|~I|~DSvBhQDYnF@WF@bFAKFJSFTvFS~F]OFfxFaOFfWFfaFhqFoDFsiF~eFqXFxSF`aFY~FQmFKfFFeFGEFCdFBqF@~FAFF@nF@fF@YF@eFXpI|~@_eBlX@SYD~`FRtF^EFBLGogBUQBUhFNDFLt@UU@B~@@L@@U@@J@@K@@L@@w@@@@Bg@Ap@A_Bx@Ok?Dd@Nk?EX@Mc?Ch@Mc?Ah@JW?Ch@F{?Hx@KK?IT@Os?FH@Ns?FP@M[?Fl@Mw?E`@Nc?B|@Lc?Bd@Ng?@L@Nc?@p@NS?OK?OC?Og?O[?@D@O[?Os?Ow?A@@Og?C|@Og?FlAAX@@B@@B@@B@@B@@B@@B@@B@@B@@B@@B@@B@@B@@B@@B@~CB~CB~CB?eC~szELd@TT@BB@C]~sy@@L@@s@@r@Fk@Dn~sx@@L@@t@@q@Ct@DX~sw@@G@Au@D@@Ay@C`@qhHO_ErXHStD|`HXrCOPHXVC{@HUgBP@HSJORpHSZ~sv@@@~su@@@~st@@@~ss@@@~CB~CB~CB~CB~CB~CB~CB~CB~CB?CW

#field namevalueinstrument
group
0clock_year 2021common
1clock_doy 284common
2clock_hhmm 1313common
3battery 13.41diagnostics
4int_temp 18.79diagnostics
5water_level 51.3diagnostics
6gps_time 1255diagnostics
7gps_seconds 15diagnostics
8gps_lat_degrees 42diagnostics
9gps_lat_minutes 31diagnostics
10gps_lat_minutes_fraction 0.446diagnostics
11gps_lon_degrees 70diagnostics
12gps_lon_minutes 33diagnostics
13gps_lon_minutes_fraction 0.962diagnostics
14gps_date 1110diagnostics
15gps_alt_lat_degrees 42diagnostics
16gps_alt_lat_minutes 31diagnostics
17gps_alt_lat_minutes 0.433diagnostics
18gps_alt_lon_degrees -70diagnostics
19gps_alt_lon_minutes 33diagnostics
20gps_alt_lon_minutes_fraction 0.984diagnostics
21air_temperature 16.56met
22wind_min 2.548met
23wind_gust 4.743met
24wind_speed_sc 3.843met
25wind_direction_uv 73.29met
26wind_direction_uv_stddev 13.48met
27wind_gust_1s 5.096met
28wind_percent_good -7998met
29compass 16.03met
30compass_stddev 42.41met
31visibility_counts 2494met
32min_visibility_counts 2494met
33max_visibility_counts 2494met
34barometric_pressure_counts 1829met
35barometric_pressure_min_counts 1827met
36barometric_pressure_max_counts 1832met
37barometric_pressure_stddev_counts 0.585met
38wind_2_min 2.37met
39wind_2_gust 4.466met
40wind_2_speed_sc 3.839met
41wind_2_direction_uv 69.68met
42wind_2_direction_uv_stddev 12.52met
43wind_2_gust_1s 5.57met
44wind_2_percent_good 1met
45wind_gust_hourly 596met
46wind_gust_hourly_time -7998met
47wind_gust_hourly_seconds -7998met
48wind_2_gust_hourly -7998met
49wind_2_gust_hourly_time -7998met
50wind_2_gust_hourly_seconds -7998met
51wind_2_total_1s_samples -7998met
52wind_2_valid_1s_samples -7998met
53dissolved_oxygen 205.4optode
54oxygen_saturation 73.02optode
55temperature 10.82optode
56oxygen_counts -7998aanderaa
57signal_strength_counts-43.93aanderaa
58tilt_counts 5.419aanderaa
59checksum -1591common
60conductivity_integer_1m 0ct
61conductivity_1_fraction_1m 0ct
62temperature_1m 0ct
63pressure_1m 0ct
64conductivity_integer_10m 4ct
65conductivity_fraction_10m 0.095ct
66temperature_10m 16.73ct
67pressure_10m 6.264ct
68conductivity_integer_20m 41ct
69conductivity_fraction_20m 0.325ct
70temperature_20m 16.88ct
71pressure_20m 0ct
72conductivity_integer_50m 3ct
73conductivity_fraction_50m 0.675ct
74temperature_50m 11.11ct
75pressure_50m 50.38ct
76conductivity_integer_deep -7998ct
77conductivity_fraction_deep -7998ct
78temperature_deep -7998ct
79pressure_deep -7998ct
80spare -7998common
81current_speed_counts 12.7aanderaa
82current_direction_counts 257.7aanderaa
83temperature_counts 16.46aanderaa
84volts 0.023accelerometer
85volts 0.034accelerometer
86volts 0.075accelerometer
87volts 0.659accelerometer
88volts 1.334accelerometer
89volts 1.278accelerometer
90volts 1.871accelerometer
91volts 2.488accelerometer
92volts 2.127accelerometer
93volts 2.455accelerometer
94volts 2.465accelerometer
95volts 2.609accelerometer
96volts 3.012accelerometer
97volts 3.305accelerometer
98volts 4.005accelerometer
99volts 3.16accelerometer
100volts 3.603accelerometer
101volts 2.081accelerometer
102volts 1.662accelerometer
103volts 1.133accelerometer
104volts 0.742accelerometer
105volts 0.421accelerometer
106volts 0.453accelerometer
107volts 0.228accelerometer
108volts 0.177accelerometer
109volts 0.062accelerometer
110volts 0.07accelerometer
111volts 0.046accelerometer
112volts 0.038accelerometer
113volts 0.025accelerometer
114volts 0.037accelerometer
115o2_voltage 1.584ct
116pressure -7998ct
117year 2021waves3
118doy 284waves3
119hhmm 1241waves3
120seconds 40waves3
121significant_wave_height_3 1.204waves3
122maximum_wave_height_3 1.925waves3
123dominant_wave_frequency_3 0.14waves3
124dominant_wave_period_3 7.143waves3
125mean_wave_direction_3 136.1waves3
126principal_wave_direction_3 138.4waves3
127R1_3 0.9waves3
128R2_3 0.82waves3
129checksum 1365common
130ens3 190doppler
131ens212doppler
132year21doppler
133month10doppler
134day11doppler
135hour12doppler
136minute55doppler
137ens10doppler
138amps167doppler
139volts112doppler
140int_temp95doppler
141current_u_counts11776doppler
142current_v_counts64255doppler
143current_u_counts18688doppler
144current_v_counts60159doppler
145current_u_counts22016doppler
146current_v_counts55551doppler
147current_u_counts14848doppler
148current_v_counts55551doppler
149current_u_counts6656doppler
150current_v_counts42495doppler
151current_u_counts14848doppler
152current_v_counts28415doppler
153current_u_counts36352doppler
154current_v_counts45823doppler
155current_u_counts38144doppler
156current_v_counts64767doppler
157current_u_counts25088doppler
158current_v_counts60671doppler
159current_u_counts25600doppler
160current_v_counts55039doppler
161current_u_counts27392doppler
162current_v_counts56831doppler
163current_u_counts22528doppler
164current_v_counts59647doppler
165current_u_counts12032doppler
166current_v_counts51455doppler
167current_u_counts10496doppler
168current_v_counts59903doppler
169current_u_counts768doppler
170current_v_counts59647doppler
171current_u_counts3072doppler
172current_v_counts58623doppler
173current_u_counts62207doppler
174current_v_counts61695doppler
175current_u_counts63999doppler
176current_v_counts63231doppler
177current_u_counts256doppler
178current_v_counts63231doppler
179current_u_counts64767doppler
180current_v_counts65023doppler
181current_u_counts4096doppler
182current_v_counts63999doppler
183current_u_counts16128doppler
184current_v_counts63999doppler
185current_u_counts27393doppler
186current_v_counts5632doppler
187current_u_counts128doppler
188current_v_counts128doppler
189current_u_counts128doppler
190current_v_counts128doppler
191current_u_counts128doppler
192current_v_counts128doppler
193current_u_counts128doppler
194current_v_counts128doppler
195current_u_counts128doppler
196current_v_counts128doppler
197current_u_counts128doppler
198current_v_counts128doppler
199current_u_counts128doppler
200current_v_counts128doppler
201spare-7998common
202spare-7998common
203spare-7998common
204checksum-1725common
205dh4_id-4870optics
206optics_date21284optics
207optics_hhmm1300optics
208volts130optics
209disk_free221optics
210flntus_id-4871optics
211flntus_sensor_type12optics
212flntus_num_samples_collected51optics
213flntus_num_samples_used50optics
214chlorophyll_fluorescence_counts427optics
215turbidity_counts302optics
216spare_optics-4872common
217spare_optics12common
218spare_optics52common
219spare_optics49common
220spare_optics244common
221spare_optics280common
222spare_optics-4873common
223spare_optics7common
224spare_optics117common
225spare_optics256common
226spare_optics121common
227spare_optics224common
228spare_optics3176common
229spare_optics33759common
230spare_optics23704common
231spare_optics34036common
232spare_optics20256common
233spare_optics34354common
234spare_optics13264common
235spare_optics34326common
236spare_optics16064common
237spare_optics34151common
238spare_optics9216common
239spare_optics33994common
240spare_optics62640common
241spare_optics34010common
242spare_optics-4874common
243spare_optics0common
244spare_optics-4875common
245spare_optics0common
246spare_optics-4876common
247spare_optics0common
248spare_optics-4877common
249spare_optics0common
250spare_optics-7998common
251spare_optics-7998common
252spare_optics-7998common
253spare_optics-7998common
254spare_optics-7998common
255spare_optics-7998common
256spare_optics-7998common
257spare_optics-7998common
258spare_optics-7998common
259checksum-3881common