Decoded GOES message
A0144 20-Jul-2021 00:28:35 GOES DCP id=04427630
TX time:20-Jul-2021 00:28:35
failure code:G
signal strength:37
data quality:N
message length:782
message:
0442763021201002835G37+0NN181EUB00782@@_eB_ZF@@DTdDdtEPZ@dsE@DEAhDp\FGCEmXDsdFON@]sEAhDp\FGBMmXDsdFOXD^TFILF[dFScBftDQDF[dI|~BwWDUO@f?@f?@f?@[^@[]@[_FDTFFZFZnFTUBfPDUgFfzFOhC]HI|~I|~I|~I|~I|~I|~I|~BjBBNVDN@I|~LjTFtmKSgF~`FAcD_WF@@F~`FCED\gG`HD{XFHyDVKF@@FnxFF{DNCEN_I|~I|~I|~I|~I|~DijBgND^iF@GF@EF@KF@hFBUFDJFDqFC|FHLFIGFLHFQ^FR[FIyFMuFKkFL~FM~FIfFEoFDjFBYFAVFABF@gF@XF@VF@IF@EF@DF@DF[`I|~@_eB_P@deD~`FFQFJAFBjG[zBVGBUGFM\FMf@eI@Ci@@D@@U@@G@@S@@W@@w@@@@Bo@As@A[@O?@T@Ow~IS?HO?Bc?A`@B{?AD@Dk?No?Dc?Lo?Cw?Lo?Dg?M_?Es?MK?Gs?LS?G??N{?Gg?BX@Hk?CH@KW?Oo?Oo?Og?Og?OW?OS?OG?O??OK?Oo?OG?N{?O_?OK?O??OK?OO?N[?DD@No?@B@@B@@B@@B@@B@@B@@B@@B@@B@@B@@B@@B@~CB~CB~CB~|r~szEKQ@@@@B@@Cu~sy@@L@@s@@r@CH@Bb~sx@@L@@t@@q@A}@BL~sw@@G@Au@D@@Ay@C`AjpHAFJhxHA[IkXHAuCCxHAj@rxHAVN]pHArHvXHAr~sv@@@~su@@@~st@@@~ss@@@~CB~CB~CB~CB~CB~CB~CB~CB~CB?j@

#field namevalueinstrument
group
1clock_year 2021common
2clock_doy 201common
3clock_hhmm 0common
4battery 13.16diagnostics
5int_temp 23.56diagnostics
6water_level 51.46diagnostics
7gps_time 2355diagnostics
8gps_seconds 41diagnostics
9gps_lat_degrees 42diagnostics
10gps_lat_minutes 31diagnostics
11gps_lat_minutes_fraction 0.451diagnostics
12gps_lon_degrees 70diagnostics
13gps_lon_minutes 33diagnostics
14gps_lon_minutes_fraction 0.974diagnostics
15gps_date 1907diagnostics
16gps_alt_lat_degrees 42diagnostics
17gps_alt_lat_minutes 31diagnostics
18gps_alt_lat_minutes 0.45diagnostics
19gps_alt_lon_degrees -70diagnostics
20gps_alt_lon_minutes 33diagnostics
21gps_alt_lon_minutes_fraction 0.984diagnostics
22air_temperature 19.4met
23wind_min 0.588met
24wind_gust 1.764met
25wind_speed_sc 1.251met
26wind_direction_uv 248.4met
27wind_direction_uv_stddev 10.92met
28wind_gust_1s 1.764met
29wind_percent_good -7998met
30compass 354.3met
31compass_stddev 13.59met
32visibility_counts 2495met
33min_visibility_counts 2495met
34max_visibility_counts 2495met
35barometric_pressure_counts 1758met
36barometric_pressure_min_counts 1757met
37barometric_pressure_max_counts 1759met
38barometric_pressure_stddev_counts 0.276met
39wind_2_min 0.41met
40wind_2_gust 1.71met
41wind_2_speed_sc 1.301met
42wind_2_direction_uv 244.8met
43wind_2_direction_uv_stddev 13.83met
44wind_2_gust_1s 2.49met
45wind_2_percent_good 1met
46wind_gust_hourly 596met
47wind_gust_hourly_time -7998met
48wind_gust_hourly_seconds -7998met
49wind_2_gust_hourly -7998met
50wind_2_gust_hourly_time -7998met
51wind_2_gust_hourly_seconds -7998met
52wind_2_total_1s_samples -7998met
53wind_2_valid_1s_samples -7998met
54dissolved_oxygen 269optode
55oxygen_saturation 91.8optode
56temperature 8.96optode
57oxygen_counts -7998aanderaa
58signal_strength_counts-27.08aanderaa
59tilt_counts 3.373aanderaa
60checksum-535.1common
61conductivity_integer_1m 4ct
62conductivity_1_fraction_1m 0.099ct
63temperature_1m 20.07ct
64pressure_1m 0ct
65conductivity_integer_10m 4ct
66conductivity_fraction_10m 0.197ct
67temperature_10m 18.31ct
68pressure_10m 6.152ct
69conductivity_integer_20m 38ct
70conductivity_fraction_20m 0.569ct
71temperature_20m 14.19ct
72pressure_20m 0ct
73conductivity_integer_50m 3ct
74conductivity_fraction_50m 0.443ct
75temperature_50m 8.99ct
76pressure_50m 50.23ct
77conductivity_integer_deep -7998ct
78conductivity_fraction_deep -7998ct
79temperature_deep -7998ct
80pressure_deep -7998ct
81spare -7998common
82current_speed_counts 26.66aanderaa
83current_direction_counts 251aanderaa
84temperature_counts 19.61aanderaa
85volts 0.007accelerometer
86volts 0.005accelerometer
87volts 0.011accelerometer
88volts 0.04accelerometer
89volts 0.149accelerometer
90volts 0.266accelerometer
91volts 0.305accelerometer
92volts 0.252accelerometer
93volts 0.524accelerometer
94volts 0.583accelerometer
95volts 0.776accelerometer
96volts 1.118accelerometer
97volts 1.179accelerometer
98volts 0.633accelerometer
99volts 0.885accelerometer
100volts 0.747accelerometer
101volts 0.83accelerometer
102volts 0.894accelerometer
103volts 0.614accelerometer
104volts 0.367accelerometer
105volts 0.298accelerometer
106volts 0.153accelerometer
107volts 0.086accelerometer
108volts 0.066accelerometer
109volts 0.039accelerometer
110volts 0.024accelerometer
111volts 0.022accelerometer
112volts 0.009accelerometer
113volts 0.005accelerometer
114volts 0.004accelerometer
115volts 0.004accelerometer
116o2_voltage 1.76ct
117pressure -7998ct
118year 2021waves3
119doy 200waves3
120hhmm 2341waves3
121seconds 40waves3
122significant_wave_height_3 0.401waves3
123maximum_wave_height_3 0.641waves3
124dominant_wave_frequency_3 0.17waves3
125dominant_wave_period_3 5.882waves3
126mean_wave_direction_3 141.5waves3
127principal_wave_direction_3 135.1waves3
128R1_3 0.86waves3
129R2_3 0.87waves3
130checksum 2377common
131ens3 233doppler
132ens24doppler
133year21doppler
134month7doppler
135day19doppler
136hour23doppler
137minute55doppler
138ens10doppler
139amps175doppler
140volts115doppler
141int_temp91doppler
142current_u_counts1023doppler
143current_v_counts1280doppler
144current_u_counts65022doppler
145current_v_counts38143doppler
146current_u_counts33791doppler
147current_v_counts10495doppler
148current_u_counts6144doppler
149current_v_counts12031doppler
150current_u_counts4352doppler
151current_v_counts19199doppler
152current_u_counts60415doppler
153current_v_counts18687doppler
154current_u_counts52223doppler
155current_v_counts15871doppler
156current_u_counts52223doppler
157current_v_counts18943doppler
158current_u_counts55295doppler
159current_v_counts23807doppler
160current_u_counts54015doppler
161current_v_counts31999doppler
162current_u_counts50431doppler
163current_v_counts32767doppler
164current_u_counts61183doppler
165current_v_counts31231doppler
166current_u_counts9728doppler
167current_v_counts35583doppler
168current_u_counts12800doppler
169current_v_counts46591doppler
170current_u_counts64511doppler
171current_v_counts64511doppler
172current_u_counts63999doppler
173current_v_counts63999doppler
174current_u_counts62975doppler
175current_v_counts62719doppler
176current_u_counts61951doppler
177current_v_counts65535doppler
178current_u_counts62207doppler
179current_v_counts64511doppler
180current_u_counts61951doppler
181current_v_counts61183doppler
182current_u_counts63487doppler
183current_v_counts62207doppler
184current_u_counts65535doppler
185current_v_counts62207doppler
186current_u_counts62463doppler
187current_v_counts59135doppler
188current_u_counts16640doppler
189current_v_counts60415doppler
190current_u_counts128doppler
191current_v_counts128doppler
192current_u_counts128doppler
193current_v_counts128doppler
194current_u_counts128doppler
195current_v_counts128doppler
196current_u_counts128doppler
197current_v_counts128doppler
198current_u_counts128doppler
199current_v_counts128doppler
200current_u_counts128doppler
201current_v_counts128doppler
202spare-7998common
203spare-7998common
204spare-7998common
205checksum-4302common
206dh4_id-4870optics
207optics_date21201optics
208optics_hhmm0optics
209volts128optics
210disk_free245optics
211flntus_id-4871optics
212flntus_sensor_type12optics
213flntus_num_samples_collected51optics
214flntus_num_samples_used50optics
215chlorophyll_fluorescence_counts200optics
216turbidity_counts162optics
217spare_optics-4872common
218spare_optics12common
219spare_optics52common
220spare_optics49common
221spare_optics125common
222spare_optics140common
223spare_optics-4873common
224spare_optics7common
225spare_optics117common
226spare_optics256common
227spare_optics121common
228spare_optics224common
229spare_optics6832common
230spare_optics32838common
231spare_optics43576common
232spare_optics32859common
233spare_optics39640common
234spare_optics32885common
235spare_optics12536common
236spare_optics32874common
237spare_optics3256common
238spare_optics32854common
239spare_optics59248common
240spare_optics32882common
241spare_optics36248common
242spare_optics32882common
243spare_optics-4874common
244spare_optics0common
245spare_optics-4875common
246spare_optics0common
247spare_optics-4876common
248spare_optics0common
249spare_optics-4877common
250spare_optics0common
251spare_optics-7998common
252spare_optics-7998common
253spare_optics-7998common
254spare_optics-7998common
255spare_optics-7998common
256spare_optics-7998common
257spare_optics-7998common
258spare_optics-7998common
259spare_optics-7998common
260checksum-1408common