Decoded GOES message
A0143 10-Jan-2021 13:26:35 GOES DCP id=0441F72A
TX time:10-Jan-2021 13:26:35
failure code:?
signal strength:32
data quality:P
message length:20
message:
0441F72A21010132635?32+0HP181EN100020@@_eDOh@T`DRZGX$$$

#field namevalueinstrument
group
0clock_year 2021common
1clock_doy 10common
2clock_hhmm 1312common
3battery 11.78diagnostics
4int_temp 5.658diagnostics
5water_level 23.4diagnostics
6gps_timediagnostics