Decoded GOES message
A0142 28-Jun-2020 11:28:35 GOES DCP id=04427630
TX time:28-Jun-2020 11:28:35
failure code:G
signal strength:40
data quality:N
message length:767
message:
0442763020180112835G40+0NN181EUP00767@@_dB\H@QXDUmD`lEPJ@P_DZdEAhDp\FE|EmXDsdFNmA|}EAhDp\FEoMmXDsdFNvD[tFq@GJGFzeBjhDMtGF\I|~B[FDNG@f?@f?@f?@Zn@Zm@ZoFEmFpzGEPF~~BmkGK}GLFFOhBeVI|~I|~I|~I|~I|~I|~I|~BlvBNOGZTI|~BXBGUXJNFF@@F@@F@@Dr@FLVGuLFnxFB]GZrI|~I|~I|~I|~I|~I|~I|~I|~I|~I|~I|~I|~F@@@?\A|}F@BF@EF@SFA`FAKFA^FD}FFkFD[FGuFGLFLGFN}FK~FNNFSiFMzFLIFIvFGbFFSFDHFC[FAZFAKF@sF@XF@WF@RF@NF@NFYAF@A@_dB\H@PQE@DFFSFJDFBBGxLBSuBUOFLjFIbAIZ@Ca@@W@@T@@F@@\@@J@@x@@@@Bc@Am@A_Ko?E{?F??Bc?IS?Ec?NK?FS?L{?Gw?M[?JO?K??Kw?K_?K??LO?LG?Ko?L_?Jo?M_?Jo?Ng?KC?N??L{?OK?OS?@d@Nw?AH@NS?A|@NK?Ad@NG?Al@NW?A|@NK?A|@N_?At@Ng?B@@Ng?Ad@A@@@`@@B@@B@@B@@B@@B@@B@@B@@B@@B@@B@~CB~CB~CB?NW~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB?bR

#field namevalueinstrument
group
0clock_year 2020common
1clock_doy 180common
2clock_hhmm 1112common
3battery 13.89diagnostics
4int_temp 20.92diagnostics
5water_level 51.3diagnostics
6gps_time 1055diagnostics
7gps_seconds 17diagnostics
8gps_lat_degrees 42diagnostics
9gps_lat_minutes 31diagnostics
10gps_lat_minutes_fraction 0.38diagnostics
11gps_lon_degrees 70diagnostics
12gps_lon_minutes 33diagnostics
13gps_lon_minutes_fraction 0.941diagnostics
14gps_date 7997diagnostics
15gps_alt_lat_degrees 42diagnostics
16gps_alt_lat_minutes 31diagnostics
17gps_alt_lat_minutes 0.367diagnostics
18gps_alt_lon_degrees -70diagnostics
19gps_alt_lon_minutes 33diagnostics
20gps_alt_lon_minutes_fraction 0.95diagnostics
21air_temperature 17.8met
22wind_min 3.136met
23wind_gust 4.743met
24wind_speed_sc 3.749met
25wind_direction_uv 272.8met
26wind_direction_uv_stddev 8.84met
27wind_gust_1s 4.508met
28wind_percent_good -7998met
29compass 173.4met
30compass_stddev 9.03met
31visibility_counts 2495met
32min_visibility_counts 2495met
33max_visibility_counts 2495met
34barometric_pressure_counts 1710met
35barometric_pressure_min_counts 1709met
36barometric_pressure_max_counts 1711met
37barometric_pressure_stddev_counts 0.365met
38wind_2_min 3.13met
39wind_2_gust 4.432met
40wind_2_speed_sc 4.03met
41wind_2_direction_uv 292.3met
42wind_2_direction_uv_stddev 4.861met
43wind_2_gust_1s 4.87met
44wind_2_percent_good 1met
45wind_gust_hourly 239met
46wind_gust_hourly_time -7998met
47wind_gust_hourly_seconds -7998met
48wind_2_gust_hourly -7998met
49wind_2_gust_hourly_time -7998met
50wind_2_gust_hourly_seconds -7998met
51wind_2_total_1s_samples -7998met
52wind_2_valid_1s_samples -7998met
53dissolved_oxygen 287optode
54oxygen_saturation 91.1optode
55temperature 5.78optode
56oxygen_counts -7998aanderaa
57signal_strength_counts 153.8aanderaa
58tilt_counts 5.464aanderaa
59checksum -90.2common
60conductivity_integer 0ct
61conductivity_1_fraction 0ct
62temperature_ 0ct
63conductivity_integer 32ct
64conductivity_fraction 0.79ct
65temperature 7.5ct
66conductivity_integer 3ct
67conductivity_fraction 0.157ct
68temperature 5.81ct
69conductivity_integer -7998ct
70conductivity_fraction -7998ct
71temperature -7998ct
72conductivity_integer -7998ct
73conductivity_fraction -7998ct
74temperature -7998ct
75conductivity_integer -7998ct
76conductivity_fraction -7998ct
77temperature -7998ct
78conductivity_integer -7998ct
79conductivity_fraction -7998ct
80temperature -7998ct
81current_speed_counts 0aanderaa
82current_direction_counts 4060aanderaa
83temperature_counts 7997aanderaa
84volts 0.002accelerometer
85volts 0.005accelerometer
86volts 0.019accelerometer
87volts 0.096accelerometer
88volts 0.075accelerometer
89volts 0.094accelerometer
90volts 0.317accelerometer
91volts 0.427accelerometer
92volts 0.283accelerometer
93volts 0.501accelerometer
94volts 0.46accelerometer
95volts 0.775accelerometer
96volts 0.957accelerometer
97volts 0.766accelerometer
98volts 0.91accelerometer
99volts 1.257accelerometer
100volts 0.89accelerometer
101volts 0.777accelerometer
102volts 0.63accelerometer
103volts 0.482accelerometer
104volts 0.403accelerometer
105volts 0.264accelerometer
106volts 0.219accelerometer
107volts 0.09accelerometer
108volts 0.075accelerometer
109volts 0.051accelerometer
110volts 0.024accelerometer
111volts 0.023accelerometer
112volts 0.018accelerometer
113volts 0.014accelerometer
114volts 0.014accelerometer
115o2_voltage 1.601ct
116pressure 0.001ct
117year 2020waves3
118doy 180waves3
119hhmm 1041waves3
120seconds 41waves3
121significant_wave_height_3 0.403waves3
122maximum_wave_height_3 0.644waves3
123dominant_wave_frequency_3 0.13waves3
124dominant_wave_period_3 7.692waves3
125mean_wave_direction_3 126.9waves3
126principal_wave_direction_3 135.9waves3
127R1_3 0.81waves3
128R2_3 0.61waves3
129checksum 4698common
130ens3225doppler
131ens223doppler
132year20doppler
133month6doppler
134day28doppler
135hour10doppler
136minute56doppler
137ens10doppler
138amps163doppler
139volts109doppler
140int_temp95doppler
141current_u_counts48127doppler
142current_v_counts24319doppler
143current_u_counts28671doppler
144current_v_counts10495doppler
145current_u_counts38143doppler
146current_v_counts22783doppler
147current_u_counts58111doppler
148current_v_counts25855doppler
149current_u_counts52991doppler
150current_v_counts32255doppler
151current_u_counts55039doppler
152current_v_counts41983doppler
153current_u_counts49151doppler
154current_v_counts48639doppler
155current_u_counts47103doppler
156current_v_counts49151doppler
157current_u_counts50175doppler
158current_v_counts49663doppler
159current_u_counts48127doppler
160current_v_counts51199doppler
161current_u_counts44031doppler
162current_v_counts55295doppler
163current_u_counts44031doppler
164current_v_counts59903doppler
165current_u_counts45311doppler
166current_v_counts61439doppler
167current_u_counts52991doppler
168current_v_counts62207doppler
169current_u_counts62719doppler
170current_v_counts2304doppler
171current_u_counts60927doppler
172current_v_counts4608doppler
173current_u_counts58623doppler
174current_v_counts7936doppler
175current_u_counts58111doppler
176current_v_counts6400doppler
177current_u_counts57855doppler
178current_v_counts6912doppler
179current_u_counts58879doppler
180current_v_counts7936doppler
181current_u_counts58111doppler
182current_v_counts7936doppler
183current_u_counts59391doppler
184current_v_counts7424doppler
185current_u_counts59903doppler
186current_v_counts8192doppler
187current_u_counts59903doppler
188current_v_counts6400doppler
189current_u_counts4096doppler
190current_v_counts2048doppler
191current_u_counts128doppler
192current_v_counts128doppler
193current_u_counts128doppler
194current_v_counts128doppler
195current_u_counts128doppler
196current_v_counts128doppler
197current_u_counts128doppler
198current_v_counts128doppler
199current_u_counts128doppler
200current_v_counts128doppler
201spare-7998common
202spare-7998common
203spare-7998common
204checksum-3177common
205dh4_id-7998optics
206optics_date-7998optics
207optics_hhmm-7998optics
208volts-7998optics
209disk_free-7998optics
210flntus_id-7998optics
211flntus_sensor_type-7998optics
212flntus_num_samples_collected-7998optics
213flntus_num_samples_used-7998optics
214chlorophyll_fluorescence_counts-7998optics
215turbidity_counts-7998optics
216spare_optics-7998common
217spare_optics-7998common
218spare_optics-7998common
219spare_optics-7998common
220spare_optics-7998common
221spare_optics-7998common
222spare_optics-7998common
223spare_optics-7998common
224spare_optics-7998common
225spare_optics-7998common
226spare_optics-7998common
227spare_optics-7998common
228spare_optics-7998common
229spare_optics-7998common
230spare_optics-7998common
231spare_optics-7998common
232spare_optics-7998common
233spare_optics-7998common
234spare_optics-7998common
235spare_optics-7998common
236spare_optics-7998common
237spare_optics-7998common
238spare_optics-7998common
239spare_optics-7998common
240spare_optics-7998common
241spare_optics-7998common
242spare_optics-7998common
243spare_optics-7998common
244spare_optics-7998common
245spare_optics-7998common
246spare_optics-7998common
247spare_optics-7998common
248spare_optics-7998common
249spare_optics-7998common
250spare_optics-7998common
251spare_optics-7998common
252spare_optics-7998common
253spare_optics-7998common
254spare_optics-1902common
255spare_opticscommon