Decoded GOES message
A0142 11-Jun-2020 21:28:35 GOES DCP id=04427630
TX time:11-Jun-2020 21:28:35
failure code:G
signal strength:37
data quality:F
message length:767
message:
0442763020163212835G37+0NF181EN200767@@_dBY^@a@DTQD^nEPS@`GD~`EAhDp\FFFEmXDsdFNhA|}EAhDp\FE?MmXDsdFNvDY`GF\GsqG`UB`^DSDGz`I|~BQdDtA@f~@f~@f~@[v@[t@[xFMwGEDGpxGdiBcUGtIDLhFOhBeVI|~I|~I|~I|~I|~I|~I|~BjwBMcGWtI|~BQND[OHozF@@F@@F@@Dp\FLbGb~FnxFBTGXiI|~I|~I|~I|~I|~I|~I|~I|~I|~I|~I|~I|~F@@@?\A|}F@wF@gF@nFB|FObFsYFpyF~AGI@GAHGBSGOWGFoGC^FtvG[wGKKGGuFo~FaCF[NFLpFKWFDfFCdFCdFBEFAbFAMFAHF@lFYtF@A@_dBY^@_yD~`FRvF^GFBtGVtBUoBU?FMfFJJCuT@AS@@V@@T@@F@@K@@T@@x@@@@Ba@An@AbO{?H??Ec?MK?F??LW?Ec?No?C_?NW?BC?L{?Aw?Lk?B[?MS?CO?NS?Dg?Ow?FS?Oo?GW?Nc?HK?N{?JO?N_?Mg?NG?Ms?O{?NW?BH@Oo?Ch@Nw?BX@No?Bt@NS?BL@NO?AL@Mc?AX@MG?AT@@B@@B@@B@@B@@B@@B@HS?HL@@B@@B@@B@@B@~CB~CB~CB?rp~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB~CB?bR

#field namevalueinstrument
group
1clock_year 2020common
2clock_doy 163common
3clock_hhmm 2112common
4battery 12.97diagnostics
5int_temp 19.66diagnostics
6water_level 51.39diagnostics
7gps_time 2055diagnostics
8gps_seconds 40diagnostics
9gps_lat_degrees 42diagnostics
10gps_lat_minutes 31diagnostics
11gps_lat_minutes_fraction 0.39diagnostics
12gps_lon_degrees 70diagnostics
13gps_lon_minutes 33diagnostics
14gps_lon_minutes_fraction 0.936diagnostics
15gps_date 7997diagnostics
16gps_alt_lat_degrees 42diagnostics
17gps_alt_lat_minutes 31diagnostics
18gps_alt_lat_minutes 0.383diagnostics
19gps_alt_lon_degrees -70diagnostics
20gps_alt_lon_minutes 33diagnostics
21gps_alt_lon_minutes_fraction 0.95diagnostics
22air_temperature 16.32met
23wind_min 4.508met
24wind_gust 7.409met
25wind_speed_sc 6.165met
26wind_direction_uv 207.8met
27wind_direction_uv_stddev 12.2met
28wind_gust_1s 7.84met
29wind_percent_good -7998met
30compass 112.4met
31compass_stddev 33.29met
32visibility_counts 2494met
33min_visibility_counts 2494met
34max_visibility_counts 2494met
35barometric_pressure_counts 1782met
36barometric_pressure_min_counts 1780met
37barometric_pressure_max_counts 1784met
38barometric_pressure_stddev_counts 0.887met
39wind_2_min 4.42met
40wind_2_gust 7.224met
41wind_2_speed_sc 6.441met
42wind_2_direction_uv 226.1met
43wind_2_direction_uv_stddev 7.433met
44wind_2_gust_1s 8.08met
45wind_2_percent_good 1met
46wind_gust_hourly 239met
47wind_gust_hourly_time -7998met
48wind_gust_hourly_seconds -7998met
49wind_2_gust_hourly -7998met
50wind_2_gust_hourly_time -7998met
51wind_2_gust_hourly_seconds -7998met
52wind_2_total_1s_samples -7998met
53wind_2_valid_1s_samples -7998met
54dissolved_oxygen 274.3optode
55oxygen_saturation 86.7optode
56temperature 5.62optode
57oxygen_counts -7998aanderaa
58signal_strength_counts 110.2aanderaa
59tilt_counts 17.43aanderaa
60checksum -3066common
61conductivity_integer 0ct
62conductivity_1_fraction 0ct
63temperature_ 0ct
64conductivity_integer 31ct
65conductivity_fraction 0.802ct
66temperature 6.334ct
67conductivity_integer 3ct
68conductivity_fraction 0.148ct
69temperature 5.673ct
70conductivity_integer -7998ct
71conductivity_fraction -7998ct
72temperature -7998ct
73conductivity_integer -7998ct
74conductivity_fraction -7998ct
75temperature -7998ct
76conductivity_integer -7998ct
77conductivity_fraction -7998ct
78temperature -7998ct
79conductivity_integer -7998ct
80conductivity_fraction -7998ct
81temperature -7998ct
82current_speed_counts 0aanderaa
83current_direction_counts 4060aanderaa
84temperature_counts 7997aanderaa
85volts 0.055accelerometer
86volts 0.039accelerometer
87volts 0.046accelerometer
88volts 0.188accelerometer
89volts 0.994accelerometer
90volts 3.289accelerometer
91volts 3.129accelerometer
92volts 3.969accelerometer
93volts 4.672accelerometer
94volts 4.168accelerometer
95volts 4.243accelerometer
96volts 5.079accelerometer
97volts 4.527accelerometer
98volts 4.318accelerometer
99volts 3.382accelerometer
100volts 5.879accelerometer
101volts 4.811accelerometer
102volts 4.597accelerometer
103volts 3.07accelerometer
104volts 2.115accelerometer
105volts 1.742accelerometer
106volts 0.816accelerometer
107volts 0.727accelerometer
108volts 0.294accelerometer
109volts 0.228accelerometer
110volts 0.228accelerometer
111volts 0.133accelerometer
112volts 0.098accelerometer
113volts 0.077accelerometer
114volts 0.072accelerometer
115volts 0.044accelerometer
116o2_voltage 1.652ct
117pressure 0.001ct
118year 2020waves3
119doy 163waves3
120hhmm 2041waves3
121seconds 40waves3
122significant_wave_height_3 1.206waves3
123maximum_wave_height_3 1.927waves3
124dominant_wave_frequency_3 0.18waves3
125dominant_wave_period_3 5.556waves3
126mean_wave_direction_3 139.1waves3
127principal_wave_direction_3 140.7waves3
128R1_3 0.87waves3
129R2_3 0.65waves3
130checksum 750.8common
131ens383doppler
132ens222doppler
133year20doppler
134month6doppler
135day11doppler
136hour20doppler
137minute56doppler
138ens10doppler
139amps161doppler
140volts110doppler
141int_temp98doppler
142current_u_counts65279doppler
143current_v_counts36863doppler
144current_u_counts22783doppler
145current_v_counts54015doppler
146current_u_counts28671doppler
147current_v_counts50687doppler
148current_u_counts22783doppler
149current_v_counts60415doppler
150current_u_counts14335doppler
151current_v_counts58879doppler
152current_u_counts8447doppler
153current_v_counts52991doppler
154current_u_counts7679doppler
155current_v_counts51967doppler
156current_u_counts9983doppler
157current_v_counts54527doppler
158current_u_counts13311doppler
159current_v_counts58623doppler
160current_u_counts18943doppler
161current_v_counts65023doppler
162current_u_counts25855doppler
163current_v_counts64511doppler
164current_u_counts30207doppler
165current_v_counts59647doppler
166current_u_counts33535doppler
167current_v_counts61183doppler
168current_u_counts41983doppler
169current_v_counts59391doppler
170current_u_counts55807doppler
171current_v_counts57855doppler
172current_u_counts56575doppler
173current_v_counts65279doppler
174current_u_counts58879doppler
175current_v_counts8704doppler
176current_u_counts64511doppler
177current_v_counts14848doppler
178current_u_counts60927doppler
179current_v_counts9728doppler
180current_u_counts60415doppler
181current_v_counts11520doppler
182current_u_counts58623doppler
183current_v_counts8960doppler
184current_u_counts58367doppler
185current_v_counts4864doppler
186current_u_counts55551doppler
187current_v_counts5632doppler
188current_u_counts53759doppler
189current_v_counts5376doppler
190current_u_counts128doppler
191current_v_counts128doppler
192current_u_counts128doppler
193current_v_counts128doppler
194current_u_counts128doppler
195current_v_counts128doppler
196current_u_counts34047doppler
197current_v_counts33536doppler
198current_u_counts128doppler
199current_v_counts128doppler
200current_u_counts128doppler
201current_v_counts128doppler
202spare-7998common
203spare-7998common
204spare-7998common
205checksum-848common
206dh4_id-7998optics
207optics_date-7998optics
208optics_hhmm-7998optics
209volts-7998optics
210disk_free-7998optics
211flntus_id-7998optics
212flntus_sensor_type-7998optics
213flntus_num_samples_collected-7998optics
214flntus_num_samples_used-7998optics
215chlorophyll_fluorescence_counts-7998optics
216turbidity_counts-7998optics
217spare_optics-7998common
218spare_optics-7998common
219spare_optics-7998common
220spare_optics-7998common
221spare_optics-7998common
222spare_optics-7998common
223spare_optics-7998common
224spare_optics-7998common
225spare_optics-7998common
226spare_optics-7998common
227spare_optics-7998common
228spare_optics-7998common
229spare_optics-7998common
230spare_optics-7998common
231spare_optics-7998common
232spare_optics-7998common
233spare_optics-7998common
234spare_optics-7998common
235spare_optics-7998common
236spare_optics-7998common
237spare_optics-7998common
238spare_optics-7998common
239spare_optics-7998common
240spare_optics-7998common
241spare_optics-7998common
242spare_optics-7998common
243spare_optics-7998common
244spare_optics-7998common
245spare_optics-7998common
246spare_optics-7998common
247spare_optics-7998common
248spare_optics-7998common
249spare_optics-7998common
250spare_optics-7998common
251spare_optics-7998common
252spare_optics-7998common
253spare_optics-7998common
254spare_optics-7998common
255spare_optics-1902common
256spare_opticscommon