Decoded GOES message
A0142 12-May-2020 14:28:35 GOES DCP id=04427630
TX time:12-May-2020 14:28:35
failure code:G
signal strength:39
data quality:N
message length:767
message:
0442763020133142835G39+0NN181EUP00767@@_dBTr@VDDVpDQ`EPT@UKE@DEAhDp\FEpEmXDsdFNYA|}EAhDp\FEoMmXDsdFNfDMMGb@DRpDM?BrpDMPDSfI|~BbzDQQ@f~@f~@f~@[L@[F@[QFVLGkBDR}DNrBuvDOwDTMFOhBeVI|~I|~I|~I|~I|~I|~I|~BoNBOAG[nI|~BYjGqfIAjF@@F@@F@@Dp\FJDGfYFnxFB_G\]I|~I|~I|~I|~I|~I|~I|~I|~I|~I|~I|~I|~F@@@?\A|}FADF@|F@hFA@F@qFAIFCAFIsFtYG\tGVzDLhDO}GtnGw\GBSGaTGI_GTSF~tF^?FUjFO^FLAFHpFE]FD]FDdFB]FAqFASF]_F@A@_dBTr@T}D~`FJUFP`FDXFwsBkxBi?FL~FL`BoJ@A|@@S@@T@@E@@L@@M@@x@@@@BY@Ap@AoAt@D??Dt@G{?Cl@Fw?@T@Hk?Ms?LG?N_?OS?OW?O??OK?NC?@H@Mw?Ah@@`@@|@C@@Nw?C`@M??Cx@@t@Ns?@P@KG?CD@Fk?AP@OG?OC?M[?Nc?L[?Ok?Ks?Og?Lk?OS?MO?M{?M{?N_?NO?OG?O??@B@@B@@B@@B@@B@@B@AdABPA@T@Cd@~CB~CB~CB?Gf~tDDze@UK@BR@Cp~tC@@L@@q@@p@B^@Bs~tB@@L@@@@@@@@@@@@~tA@@L@@l@@l@At@Af~t@@@G@AQ@@F@@F@C`On`IDqHqPIRNLjPIkMAPHIPgODhI\RL]PHz}IH`IZl~s?@@@~CB~CB~CB~CB~~}

#field namevalueinstrument
group
0clock_year 2020common
1clock_doy 133common
2clock_hhmm 1412common
3battery 14.56diagnostics
4int_temp 11.2diagnostics
5water_level 51.4diagnostics
6gps_time 1355diagnostics
7gps_seconds 41diagnostics
8gps_lat_degrees 42diagnostics
9gps_lat_minutes 31diagnostics
10gps_lat_minutes_fraction 0.368diagnostics
11gps_lon_degrees 70diagnostics
12gps_lon_minutes 33diagnostics
13gps_lon_minutes_fraction 0.921diagnostics
14gps_date 7997diagnostics
15gps_alt_lat_degrees 42diagnostics
16gps_alt_lat_minutes 31diagnostics
17gps_alt_lat_minutes 0.367diagnostics
18gps_alt_lon_degrees -70diagnostics
19gps_alt_lon_minutes 33diagnostics
20gps_alt_lon_minutes_fraction 0.934diagnostics
21air_temperature 8.45met
22wind_min 6.272met
23wind_gust 12met
24wind_speed_sc 8.95met
25wind_direction_uv 324.8met
26wind_direction_uv_stddev 8.48met
27wind_gust_1s 12.54met
28wind_percent_good -7998met
29compass 223.4met
30compass_stddev 11.05met
31visibility_counts 2494met
32min_visibility_counts 2494met
33max_visibility_counts 2494met
34barometric_pressure_counts 1740met
35barometric_pressure_min_counts 1734met
36barometric_pressure_max_counts 1745met
37barometric_pressure_stddev_counts 1.42met
38wind_2_min 6.85met
39wind_2_gust 12.13met
40wind_2_speed_sc 9.46met
41wind_2_direction_uv 344.6met
42wind_2_direction_uv_stddev 10.15met
43wind_2_gust_1s 12.93met
44wind_2_percent_good 1met
45wind_gust_hourly 239met
46wind_gust_hourly_time -7998met
47wind_gust_hourly_seconds -7998met
48wind_2_gust_hourly -7998met
49wind_2_gust_hourly_time -7998met
50wind_2_gust_hourly_seconds -7998met
51wind_2_total_1s_samples -7998met
52wind_2_valid_1s_samples -7998met
53dissolved_oxygen 302.2optode
54oxygen_saturation 96.1optode
55temperature 5.87optode
56oxygen_counts -7998aanderaa
57signal_strength_counts 164.2aanderaa
58tilt_counts 7.27aanderaa
59checksum -4202common
60conductivity_integer 0ct
61conductivity_1_fraction 0ct
62temperature_ 0ct
63conductivity_integer 31ct
64conductivity_fraction 0.644ct
65temperature 6.553ct
66conductivity_integer 3ct
67conductivity_fraction 0.159ct
68temperature 5.917ct
69conductivity_integer -7998ct
70conductivity_fraction -7998ct
71temperature -7998ct
72conductivity_integer -7998ct
73conductivity_fraction -7998ct
74temperature -7998ct
75conductivity_integer -7998ct
76conductivity_fraction -7998ct
77temperature -7998ct
78conductivity_integer -7998ct
79conductivity_fraction -7998ct
80temperature -7998ct
81current_speed_counts 0aanderaa
82current_direction_counts 4060aanderaa
83temperature_counts 7997aanderaa
84volts 0.068accelerometer
85volts 0.06accelerometer
86volts 0.04accelerometer
87volts 0.064accelerometer
88volts 0.049accelerometer
89volts 0.073accelerometer
90volts 0.193accelerometer
91volts 0.627accelerometer
92volts 3.353accelerometer
93volts 5.94accelerometer
94volts 5.562accelerometer
95volts 8.08accelerometer
96volts 10.21accelerometer
97volts 7.47accelerometer
98volts 7.644accelerometer
99volts 4.243accelerometer
100volts 6.228accelerometer
101volts 4.703accelerometer
102volts 5.395accelerometer
103volts 4.02accelerometer
104volts 1.983accelerometer
105volts 1.386accelerometer
106volts 0.99accelerometer
107volts 0.769accelerometer
108volts 0.56accelerometer
109volts 0.349accelerometer
110volts 0.285accelerometer
111volts 0.292accelerometer
112volts 0.157accelerometer
113volts 0.113accelerometer
114volts 0.083accelerometer
115o2_voltage 1.887ct
116pressure 0.001ct
117year 2020waves3
118doy 133waves3
119hhmm 1341waves3
120seconds 40waves3
121significant_wave_height_3 0.661waves3
122maximum_wave_height_3 1.056waves3
123dominant_wave_frequency_3 0.28waves3
124dominant_wave_period_3 3.571waves3
125mean_wave_direction_3 280.8waves3
126principal_wave_direction_3 268.7waves3
127R1_3 0.83waves3
128R2_3 0.8waves3
129checksum 301.8common
130ens3124doppler
131ens219doppler
132year20doppler
133month5doppler
134day12doppler
135hour13doppler
136minute56doppler
137ens10doppler
138amps153doppler
139volts112doppler
140int_temp111doppler
141current_u_counts7424doppler
142current_v_counts20479doppler
143current_u_counts19712doppler
144current_v_counts32511doppler
145current_u_counts15104doppler
146current_v_counts28159doppler
147current_u_counts1280doppler
148current_v_counts35583doppler
149current_u_counts56575doppler
150current_v_counts49663doppler
151current_u_counts59391doppler
152current_v_counts62719doppler
153current_u_counts62975doppler
154current_v_counts65535doppler
155current_u_counts62207doppler
156current_v_counts57599doppler
157current_u_counts512doppler
158current_v_counts56831doppler
159current_u_counts6656doppler
160current_v_counts2048doppler
161current_u_counts3840doppler
162current_v_counts12288doppler
163current_u_counts60927doppler
164current_v_counts14336doppler
165current_u_counts57343doppler
166current_v_counts15872doppler
167current_u_counts3328doppler
168current_v_counts60671doppler
169current_u_counts1024doppler
170current_v_counts45567doppler
171current_u_counts12544doppler
172current_v_counts27391doppler
173current_u_counts5120doppler
174current_v_counts61951doppler
175current_u_counts61695doppler
176current_v_counts55039doppler
177current_u_counts59647doppler
178current_v_counts50943doppler
179current_u_counts64255doppler
180current_v_counts48383doppler
181current_u_counts63999doppler
182current_v_counts51967doppler
183current_u_counts62719doppler
184current_v_counts54271doppler
185current_u_counts57087doppler
186current_v_counts57087doppler
187current_u_counts59391doppler
188current_v_counts58367doppler
189current_u_counts61951doppler
190current_v_counts65535doppler
191current_u_counts128doppler
192current_v_counts128doppler
193current_u_counts128doppler
194current_v_counts128doppler
195current_u_counts128doppler
196current_v_counts128doppler
197current_u_counts6401doppler
198current_v_counts9217doppler
199current_u_counts1280doppler
200current_v_counts14592doppler
201spare-7998common
202spare-7998common
203spare-7998common
204checksum-3610common
205dh4_id-4860optics
206optics_date20133optics
207optics_hhmm1355optics
208volts146optics
209disk_free240optics
210flntus_id-4861optics
211flntus_sensor_type12optics
212flntus_num_samples_collected49optics
213flntus_num_samples_used48optics
214chlorophyll_fluorescence_counts158optics
215turbidity_counts179optics
216spare_optics-4862common
217spare_optics12common
218spare_optics0common
219spare_optics0common
220spare_optics0common
221spare_optics0common
222spare_optics-4863common
223spare_optics12common
224spare_optics44common
225spare_optics44common
226spare_optics116common
227spare_optics102common
228spare_optics-4864common
229spare_optics7common
230spare_optics81common
231spare_optics6common
232spare_optics6common
233spare_optics224common
234spare_optics64416common
235spare_optics37169common
236spare_optics35920common
237spare_optics38030common
238spare_optics51856common
239spare_optics39629common
240spare_optics5128common
241spare_optics37927common
242spare_optics61736common
243spare_optics38674common
244spare_optics51024common
245spare_optics36541common
246spare_optics37408common
247spare_optics38572common
248spare_optics-4865common
249spare_optics0common
250spare_optics-7998common
251spare_optics-7998common
252spare_optics-7998common
253spare_optics-7998common
254spare_optics-4163common
255spare_opticscommon