Decoded GOES message
A0142 07-Feb-2020 22:28:35 GOES DCP id=04427630
TX time:07-Feb-2020 22:28:35
failure code:G
signal strength:41
data quality:P
message length:767
message:
0442763020038222835G41+0NP181EUB00767@@_dD{X@bdDRlDOwEPR@akDY@EAhDp\FFLEmXDsdFNKA|}EAhDp\FE?MmXDsdFOGGJfDQJDbkDZNBkZDVHDcbI|~B[`D_A@eYCb[@f~@Vu@V^@WDG]QDSfDaeD[WBnjDTqDdXFOhBeVI|~I|~I|~I|~I|~I|~I|~BohBOJG\jI|~B]tNOzKXuFnxFB~G[PDr@FCaG]PFnxFCdG]gI|~I|~I|~I|~I|~I|~I|~I|~I|~I|~I|~I|~F@@@?\A|}FBFFA~FEcFiDGrND^ADdZDU]DPpG{VDQeDMuGfzGGsGSsGJ{FofFpXFpbFbsFUSFRXFIcFIUFDfFDEFDuFApFAjFA_FA\F_LF@A@_dD{X@a]D~`FkiGEoFBtGVtBXlBdXFKFFCR@N^@B\@@J@@T@@B@@G@@U@@x@@@@B]@At@AqH{?K_?HG?Lc?HO?Kg?E{?K[?DC?KG?Dw?Hc?Dc?Hs?DW?H??DG?Ho?ES?JG?Fc?J{?GW?KK?Go?Fc?ID@IT@I|@Lt@F`@@h@B_~Fp@@T@Dh@@X@E\@LW?O??Ap@Bp@CD@DL@Gx@MD@DL@JL@Dp@Dx@Gh@E|@G??@@@F_?Og?Iw?KH@F?~NXC~CB~CB~CB?UG~tDDyF@am@Ax@C{~tC@@L@@q@@p@Aj@DD~tB@@L@@@@@@@@@@@@~tA@@L@@l@@l@AO@AR~t@@@G@AQ@@F@@F@C`M}pH@`B^pH@oBKpH@uO_XH@gEqPH@TEUxH@[J{@H@_~s?@@@~CB~CB~CB~CB?Rh

#field namevalueinstrument
group
1clock_year 2020common
2clock_doy 38common
3clock_hhmm 2212common
4battery 11.96diagnostics
5int_temp 10.15diagnostics
6water_level 51.38diagnostics
7gps_time 2155diagnostics
8gps_seconds 16diagnostics
9gps_lat_degrees 42diagnostics
10gps_lat_minutes 31diagnostics
11gps_lat_minutes_fraction 0.396diagnostics
12gps_lon_degrees 70diagnostics
13gps_lon_minutes 33diagnostics
14gps_lon_minutes_fraction 0.907diagnostics
15gps_date 7997diagnostics
16gps_alt_lat_degrees 42diagnostics
17gps_alt_lat_minutes 31diagnostics
18gps_alt_lat_minutes 0.383diagnostics
19gps_alt_lon_degrees -70diagnostics
20gps_alt_lon_minutes 33diagnostics
21gps_alt_lon_minutes_fraction 0.967diagnostics
22air_temperature 4.774met
23wind_min 10.98met
24wind_gust 22.19met
25wind_speed_sc 16.78met
26wind_direction_uv 277.8met
27wind_direction_uv_stddev 14.16met
28wind_gust_1s 22.74met
29wind_percent_good -7998met
30compass 176met
31compass_stddev 19.85met
32visibility_counts 2393met
33min_visibility_counts 629.9met
34max_visibility_counts 2494met
35barometric_pressure_counts 1461met
36barometric_pressure_min_counts 1438met
37barometric_pressure_max_counts 1476met
38barometric_pressure_stddev_counts 5.969met
39wind_2_min 12.54met
40wind_2_gust 21.49met
41wind_2_speed_sc 17.51met
42wind_2_direction_uv 298.6met
43wind_2_direction_uv_stddev 13.29met
44wind_2_gust_1s 23.28met
45wind_2_percent_good 1met
46wind_gust_hourly 239met
47wind_gust_hourly_time -7998met
48wind_gust_hourly_seconds -7998met
49wind_2_gust_hourly -7998met
50wind_2_gust_hourly_time -7998met
51wind_2_gust_hourly_seconds -7998met
52wind_2_total_1s_samples -7998met
53wind_2_valid_1s_samples -7998met
54dissolved_oxygen 304.8optode
55oxygen_saturation 97optode
56temperature 5.93optode
57oxygen_counts -7998aanderaa
58signal_strength_counts 190.8aanderaa
59tilt_counts-1.018aanderaa
60checksum-568.5common
61conductivity_integer 3ct
62conductivity_1_fraction 0.19ct
63temperature_ 5.84ct
64conductivity_integer 32ct
65conductivity_fraction 0.225ct
66temperature 5.968ct
67conductivity_integer 3ct
68conductivity_fraction 0.228ct
69temperature 5.991ct
70conductivity_integer -7998ct
71conductivity_fraction -7998ct
72temperature -7998ct
73conductivity_integer -7998ct
74conductivity_fraction -7998ct
75temperature -7998ct
76conductivity_integer -7998ct
77conductivity_fraction -7998ct
78temperature -7998ct
79conductivity_integer -7998ct
80conductivity_fraction -7998ct
81temperature -7998ct
82current_speed_counts 0aanderaa
83current_direction_counts 4060aanderaa
84temperature_counts 7997aanderaa
85volts 0.134accelerometer
86volts 0.126accelerometer
87volts 0.355accelerometer
88volts 2.628accelerometer
89volts 7.31accelerometer
90volts 19.21accelerometer
91volts 23.3accelerometer
92volts 13.73accelerometer
93volts 10.72accelerometer
94volts 7.894accelerometer
95volts 11.25accelerometer
96volts 8.85accelerometer
97volts 6.586accelerometer
98volts 4.595accelerometer
99volts 5.363accelerometer
100volts 4.795accelerometer
101volts 3.046accelerometer
102volts 3.096accelerometer
103volts 3.106accelerometer
104volts 2.227accelerometer
105volts 1.363accelerometer
106volts 1.176accelerometer
107volts 0.611accelerometer
108volts 0.597accelerometer
109volts 0.294accelerometer
110volts 0.261accelerometer
111volts 0.309accelerometer
112volts 0.112accelerometer
113volts 0.106accelerometer
114volts 0.095accelerometer
115volts 0.092accelerometer
116o2_voltage 1.996ct
117pressure 0.001ct
118year 2020waves3
119doy 38waves3
120hhmm 2141waves3
121seconds 40waves3
122significant_wave_height_3 2.793waves3
123maximum_wave_height_3 4.463waves3
124dominant_wave_frequency_3 0.18waves3
125dominant_wave_period_3 5.556waves3
126mean_wave_direction_3 158waves3
127principal_wave_direction_3 232.8waves3
128R1_3 0.71waves3
129R2_3 0.21waves3
130checksum 926common
131ens3156doppler
132ens210doppler
133year20doppler
134month2doppler
135day7doppler
136hour21doppler
137minute56doppler
138ens10doppler
139amps157doppler
140volts116doppler
141int_temp113doppler
142current_u_counts36607doppler
143current_v_counts47103doppler
144current_u_counts33279doppler
145current_v_counts51455doppler
146current_u_counts33791doppler
147current_v_counts47615doppler
148current_u_counts24319doppler
149current_v_counts46847doppler
150current_u_counts16639doppler
151current_v_counts45567doppler
152current_u_counts19967doppler
153current_v_counts35071doppler
154current_u_counts18687doppler
155current_v_counts36095doppler
156current_u_counts17919doppler
157current_v_counts36863doppler
158current_u_counts16895doppler
159current_v_counts35839doppler
160current_u_counts21759doppler
161current_v_counts41471doppler
162current_u_counts26879doppler
163current_v_counts44799doppler
164current_u_counts30207doppler
165current_v_counts45823doppler
166current_u_counts31743doppler
167current_v_counts26879doppler
168current_u_counts37120doppler
169current_v_counts38144doppler
170current_u_counts40704doppler
171current_v_counts52480doppler
172current_u_counts26624doppler
173current_v_counts2560doppler
174current_u_counts10238doppler
175current_v_counts27648doppler
176current_u_counts1280doppler
177current_v_counts18944doppler
178current_u_counts1536doppler
179current_v_counts22272doppler
180current_u_counts50687doppler
181current_v_counts65535doppler
182current_u_counts7168doppler
183current_v_counts11264doppler
184current_u_counts12544doppler
185current_v_counts17152doppler
186current_u_counts32256doppler
187current_v_counts53504doppler
188current_u_counts17152doppler
189current_v_counts41728doppler
190current_u_counts19456doppler
191current_v_counts19968doppler
192current_u_counts31232doppler
193current_v_counts24320doppler
194current_u_counts32767doppler
195current_v_counts0doppler
196current_u_counts26623doppler
197current_v_counts63999doppler
198current_u_counts40447doppler
199current_v_counts45568doppler
200current_u_counts28670doppler
201current_v_counts58883doppler
202spare-7998common
203spare-7998common
204spare-7998common
205checksum-2745common
206dh4_id-4860optics
207optics_date20038optics
208optics_hhmm2157optics
209volts120optics
210disk_free251optics
211flntus_id-4861optics
212flntus_sensor_type12optics
213flntus_num_samples_collected49optics
214flntus_num_samples_used48optics
215chlorophyll_fluorescence_counts106optics
216turbidity_counts260optics
217spare_optics-4862common
218spare_optics12common
219spare_optics0common
220spare_optics0common
221spare_optics0common
222spare_optics0common
223spare_optics-4863common
224spare_optics12common
225spare_optics44common
226spare_optics44common
227spare_optics79common
228spare_optics82common
229spare_optics-4864common
230spare_optics7common
231spare_optics81common
232spare_optics6common
233spare_optics6common
234spare_optics224common
235spare_optics57200common
236spare_optics32800common
237spare_optics10160common
238spare_optics32815common
239spare_optics8944common
240spare_optics32821common
241spare_optics63448common
242spare_optics32807common
243spare_optics23632common
244spare_optics32788common
245spare_optics21880common
246spare_optics32795common
247spare_optics44736common
248spare_optics32799common
249spare_optics-4865common
250spare_optics0common
251spare_optics-7998common
252spare_optics-7998common
253spare_optics-7998common
254spare_optics-7998common
255spare_optics-2904common
256spare_opticscommon