Decoded GOES message
A0136 06-Apr-2017 23:26:33 GOES DCP id=0441F72A
TX time:06-Apr-2017 23:26:33
failure code:?
signal strength:36
data quality:P
message length:47
message:
0441F72A17096232633?36-0HP181EXE00047b@_aBO@@dQDS_GkSEQ_@d@DhhEAhDp$1l$}$$$$OJ$$"

#field namevalueinstrument
group
1clock_year 2017common
2clock_doy 96common
3clock_hhmm 2321common
4battery 12.47diagnostics
5int_temp 6.867diagnostics
6water_level 52.15diagnostics
7gps_time 2304diagnostics
8gps_seconds 26diagnostics
9gps_lat_degrees 42diagnostics
10gps_lat_minutes 31diagnostics
11gps_lat_minutes_fraction 31.8diagnostics
12gps_lon_degrees 20.45diagnostics
13gps_lon_minutes 23.4diagnostics
14gps_lon_minutes_fraction 9.7diagnostics
15gps_date 23.38diagnostics
16gps_alt_lat_degreesdiagnostics