Decoded GOES message
A0136 15-Aug-2016 15:26:32 GOES DCP id=0441F72A
TX time:15-Aug-2016 15:26:32
failure code:G
signal strength:46
data quality:N
message length:803
message:
0441F72A16228152632G46+1NN181EXE00803b@_`Bch@WqDUwDgpEPZ@W`De`EAhDp\FFDBJ|DsdFNd@WdEAhDp\FEJJ|DsdFNfDdoFFHFTNFNDEEXDL_FU\FOhBvnGYsALyALxALy@xc@xa@xeFJcFB~FUbFOOEAbDWqFZFFOhImVImVImVImVImVImVImVImVBfmBM@DLw@LWE@DBM\HW_EDpFNID`{DxPFJhDQfDuHF@eDL~ImVImVImVImVImVImVImVImVImVImVImVImVBOTCcXCiJN@BN@AF@@F@@F@@F@@F@@F@@F@@F@@N@AF@@F@@F@@F@@F@@F@@F@@F@@F@@F@@F@@F@@F@@F@@F@@F@@F@@F@@F@@F@@F`KImV@_`Bch@VaD~`FDIFFgFFAFheBZRB[uFLtFO^Jsw@@W@@D@_`@@H@@O@@N@@x@@@@CP@Aq@AXA|@HG@p@KwOCL[@X@IS@L@IoOKLoNkOoNg@@@NsNoOWMG@l@MoAL@N_Bl@NOB|@NwAX@@D@BP@@l@@p@NWAh@O[B@@OsBT@OwA\@@L@A@@OkAD@Oo@B@@B@@B@@B@@B@@B@@B@@B@@B@@B@@B@@B@@B@@B@gebgebgeboF~tNC}d@Wa@BJ@Cj~tM@@L@@l@@k@AV@Gy~tL@@L@@f@@d@AK@AU~tK@@G@@T@Bu@Ay@C`NsxHW}B}PHfaKPPH|xEcHIvGJ^XIX}A|xHQoIrhHS[~tJ@@G@Bd@C_@Ay@C`DGxHxhEtHINIINPIRRDChJOqIqhIpqAJxIx^HoXIlTgebgebgebgebK\

#field namevalueinstrument
group
1clock_year 2016common
2clock_doy 228common
3clock_hhmm 1521common
4battery 13.99diagnostics
5int_temp 25.44diagnostics
6water_level 51.46diagnostics
7gps_time 1504diagnostics
8gps_seconds 24diagnostics
9gps_lat_degrees 42diagnostics
10gps_lat_minutes 31diagnostics
11gps_lat_minutes_fraction 0.388diagnostics
12gps_lon_degrees 70diagnostics
13gps_lon_minutes 33diagnostics
14gps_lon_minutes_fraction 0.932diagnostics
15gps_date 1508diagnostics
16gps_alt_lat_degrees 42diagnostics
17gps_alt_lat_minutes 31diagnostics
18gps_alt_lat_minutes 0.383diagnostics
19gps_alt_lon_degrees -70diagnostics
20gps_alt_lon_minutes 33diagnostics
21gps_alt_lon_minutes_fraction 0.934diagnostics
22air_temperature 23.51met
23wind_min 0.392met
24wind_gust 1.294met
25wind_speed_sc 0.9met
26wind_direction_uv 44.4met
27wind_direction_uv_stddev 7.99met
28wind_gust_1s 1.372met
29wind_percent_good 1met
30compass 350.2met
31compass_stddev 5.747met
32visibility_counts 4921met
33min_visibility_counts 4920met
34max_visibility_counts 4921met
35barometric_pressure_counts 3619met
36barometric_pressure_min_counts 3617met
37barometric_pressure_max_counts 3621met
38barometric_pressure_stddev_counts 0.675met
39wind_2_min 0.19met
40wind_2_gust 1.378met
41wind_2_speed_sc 0.975met
42wind_2_direction_uv 41.94met
43wind_2_direction_uv_stddev 15.21met
44wind_2_gust_1s 1.67met
45wind_2_percent_good 1met
46wind_gust_hourly -6998met
47wind_gust_hourly_time -6998met
48wind_gust_hourly_seconds -6998met
49wind_2_gust_hourly -6998met
50wind_2_gust_hourly_time -6998met
51wind_2_gust_hourly_seconds -6998met
52wind_2_total_1s_samples -6998met
53wind_2_valid_1s_samples -6998met
54dissolved_oxygen 247.7optode
55oxygen_saturation 83.2optode
56temperature 8.23optode
57oxygen_counts 791aanderaa
58signal_strength_counts 41aanderaa
59tilt_counts 86aanderaa
60checksum -1503common
61conductivity_integer 44ct
62conductivity_1_fraction 0.905ct
63temperature_ 21.07ct
64conductivity_integer 36ct
65conductivity_fraction 0.68ct
66temperature 11.26ct
67conductivity_integer 34ct
68conductivity_fraction 0.037ct
69temperature 8.3ct
70conductivity_integer -6998ct
71conductivity_fraction -6998ct
72temperature -6998ct
73conductivity_integer -6998ct
74conductivity_fraction -6998ct
75temperature -6998ct
76conductivity_integer -6998ct
77conductivity_fraction -6998ct
78temperature -6998ct
79conductivity_integer -6998ct
80conductivity_fraction -6998ct
81temperature -6998ct
82current_speed_counts 98aanderaa
83current_direction_counts 636aanderaa
84temperature_counts 673aanderaa
85volts-0.002accelerometer
86volts-0.001accelerometer
87volts 0accelerometer
88volts 0accelerometer
89volts 0accelerometer
90volts 0accelerometer
91volts 0accelerometer
92volts 0accelerometer
93volts 0accelerometer
94volts 0accelerometer
95volts-0.001accelerometer
96volts 0accelerometer
97volts 0accelerometer
98volts 0accelerometer
99volts 0accelerometer
100volts 0accelerometer
101volts 0accelerometer
102volts 0accelerometer
103volts 0accelerometer
104volts 0accelerometer
105volts 0accelerometer
106volts 0accelerometer
107volts 0accelerometer
108volts 0accelerometer
109volts 0accelerometer
110volts 0accelerometer
111volts 0accelerometer
112volts 0accelerometer
113volts 0accelerometer
114volts 0accelerometer
115volts 0accelerometer
116o2_voltage 2.059ct
117pressure -6998ct
118year 2016waves3
119doy 228waves3
120hhmm 1441waves3
121seconds 40waves3
122significant_wave_height_3 0.265waves3
123maximum_wave_height_3 0.423waves3
124dominant_wave_frequency_3 0.385waves3
125dominant_wave_period_3 2.597waves3
126mean_wave_direction_3 168.2waves3
127principal_wave_direction_3 178.1waves3
128R1_3 0.82waves3
129R2_3 0.99waves3
130checksum-331.9common
131ens323doppler
132ens24doppler
133year2016doppler
134month8doppler
135day15doppler
136hour14doppler
137minute56doppler
138ens10doppler
139amps208doppler
140volts113doppler
141int_temp88doppler
142current_u_counts7936doppler
143current_v_counts33279doppler
144current_u_counts3072doppler
145current_v_counts48639doppler
146current_u_counts61695doppler
147current_v_counts50943doppler
148current_u_counts1536doppler
149current_v_counts38143doppler
150current_u_counts768doppler
151current_v_counts39935doppler
152current_u_counts62207doppler
153current_v_counts52223doppler
154current_u_counts60159doppler
155current_v_counts64511doppler
156current_u_counts59903doppler
157current_v_counts0doppler
158current_u_counts60671doppler
159current_v_counts60415doppler
160current_u_counts62975doppler
161current_v_counts53759doppler
162current_u_counts2816doppler
163current_v_counts56319doppler
164current_u_counts4864doppler
165current_v_counts59391doppler
166current_u_counts11008doppler
167current_v_counts58367doppler
168current_u_counts12032doppler
169current_v_counts60927doppler
170current_u_counts5632doppler
171current_v_counts256doppler
172current_u_counts9216doppler
173current_v_counts2816doppler
174current_u_counts3072doppler
175current_v_counts58879doppler
176current_u_counts6656doppler
177current_v_counts63231doppler
178current_u_counts8192doppler
179current_v_counts64767doppler
180current_u_counts9472doppler
181current_v_counts65023doppler
182current_u_counts5888doppler
183current_v_counts768doppler
184current_u_counts4096doppler
185current_v_counts64255doppler
186current_u_counts4352doppler
187current_v_counts64511doppler
188current_u_counts128doppler
189current_v_counts128doppler
190current_u_counts128doppler
191current_v_counts128doppler
192current_u_counts128doppler
193current_v_counts128doppler
194current_u_counts128doppler
195current_v_counts128doppler
196current_u_counts128doppler
197current_v_counts128doppler
198current_u_counts128doppler
199current_v_counts128doppler
200current_u_counts128doppler
201current_v_counts128doppler
202spare-99998common
203spare-99998common
204spare-99998common
205checksum-1082common
206dh4_id-4850optics
207optics_date16228optics
208optics_hhmm1505optics
209volts138optics
210disk_free234optics
211flntus_id-4851optics
212flntus_sensor_type12optics
213flntus_num_samples_collected44optics
214flntus_num_samples_used43optics
215chlorophyll_fluorescence_counts86optics
216turbidity_counts505optics
217spare_optics-4852common
218spare_optics12common
219spare_optics38common
220spare_optics36common
221spare_optics75common
222spare_optics85common
223spare_optics-4853common
224spare_optics7common
225spare_optics20common
226spare_optics181common
227spare_optics121common
228spare_optics224common
229spare_optics60664common
230spare_optics34301common
231spare_optics12112common
232spare_optics35233common
233spare_optics46096common
234spare_optics36664common
235spare_optics22728common
236spare_optics40327common
237spare_optics42904common
238spare_optics38461common
239spare_optics7992common
240spare_optics33903common
241spare_optics40104common
242spare_optics34011common
243spare_optics-4854common
244spare_optics7common
245spare_optics164common
246spare_optics223common
247spare_optics121common
248spare_optics224common
249spare_optics16888common
250spare_optics36392common
251spare_optics23816common
252spare_optics37769common
253spare_optics37776common
254spare_optics38034common
255spare_optics16616common
256spare_optics41969common
257spare_optics40040common
258spare_optics39985common
259spare_optics4792common
260checksum40478common